Design
EN 837-1
Nominal Size in mm
63, 100, 160
Accuracy Class
NS 63: 1.6
NS 100, 160: 1.0
Scale Ranges
NS 63: 0 … 1 to 0 … 1,000 bar
NS 100: 0 … 0.6 to 0 … 1,000 bar
NS 160: 0 … 0.6 to 0 … 1,600 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure Limitation
NS 63:
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value
NS 100, 160:
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible Temperature
Ambient:
-40 … +60 °C without liquid filling
-20 … +60 °C gauges with glycerine filling (Model 233.30)
Medium:
+200 °C maximum without liquid filling
+100 °C maximum with liquid filling (Model 233.30)
Temperature Effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value
Ingress Protection
IP 65 per EN 60529 / lEC 529 (gauges with back mount: IP 55)